Hargreaves Plantar test is widely used to test the thermal stimuli responses in the study of analgesic drugs in pharmacological experiments. Experiments are easy to perform as a rodent’s hind paw is exposed to a beam of radiant heat through a transparent glass surface using plantar analgesia meter. The latency to withdraw to the heat stimulus is recorded as the time for paw withdrawal in both injured and uninjured hind paws. Our Plantar test adopts microcomputer control method to obtain the pain threshold time automatically. The device contains an emitter/detector vessel, software controller, glass panel and animal enclosures. It can be used on 12 mice, 6 rats and other animals (cats, rabbits) unrestrained.
Overview
Hargreaves Plantar test is widely used to test the thermal stimuli responses in the study of analgesic drugs in pharmacological experiments. Experiments are easy to perform as a rodent’s hind paw is exposed to a beam of radiant heat through a transparent glass surface using plantar analgesia meter. The latency to withdraw to the heat stimulus is recorded as the time for paw withdrawal in both injured and uninjured hind paws. Our Plantar test adopts microcomputer control method to obtain the pain threshold time automatically. The device contains an emitter/detector vessel, software controller, glass panel and animal enclosures. It can be used on 12 mice, 6 rats and other animals (cats, rabbits) unrestrained.
Features
Animal modular enclosures for up to 12 mice and 6 rats simultaneous simulation.
7″ LCD touch screen to set parameters (light intensity, thresholds, etc.), real time data display.
Infrared light as stimulus.
Power: 0W-150W, adjustment 1.5W stepwise.
5-100% heat intensity adjustment.
Maximum Illumination time adjustable to the second (0.01-16s).
Measurement mode: Manual
Cut-off timing: from 5 to 30 seconds to protect the rodents.
Timing accuracy: 0.01s.
Calibration with I.R. Radiometer is optional.
TTL I/O: Support external 3.3V-5V high level signal trigger, Input/Output TTL signal.
Power: AC 110-220 VAC, 50-60Hz, 150W
Sound level: <40dB
Benefits
6-12 rodent simultaneous stimulation.
Microcomputer control, measure the pain threshold time of plantar thermal stimulation in free state.
5-100% light intensity adjustment range, can be adjusted precisely according to the experiment.
Time of irradiation can be flexibly set according to the irradiation intensity, to protect animals from being burned.
Item No. | Product |
SA709 | Hargreaves Plantar Test |
SA709-01 | Plantar Test Controller Unit |
SA709-02 | Acrylic Animal Enclosure |
SA709-03 | Working Platform with Glass Pane |
SA709-04 | Emitter Vessel |
SA709-05 | Main Cable |