24/7 Tailored Support
Expert assistance. Anytime. Anywhere.
Expert assistance. Anytime. Anywhere.
24/7 ordering with stable, efficient logistics.
Certified products, high-performance solutions.
Full product range, Streamlined purchasing.
The mouse head can be easily rotated flexibility so as to adjust the level of the skull. The accuracy of mediolateral rotation perfectly solves the bleeding problem when you inject through the venous sinus. Alignment Indicator can feedback whether the height of the animal’s head is horizontal. Centering Scope helps find Bregma and Lambda points. And you don’t need to set up Bregma repeatedly.
Working environment |
Temperature:5°C~40°C Humidity: 15%~95% Air pressure: 57kPa~106kPa |
Storage environment |
Temperature:-20°C~60°C Humidity: 10%~9% Air pressure: 50 kPa ~ 106 kPa |
Power supply |
AC power: 90 V~264 V,50/60Hz DC power: 24 VDC,1.5 A,36 W The voltage fluctuation does not exceed 1% of the working voltage range. |
Category | Model | Product Description | Remark |
Stereotaxic host (without accessories) | 71001-S | Automated Stereotaxic Instrument, SGL.M, Automatic Injection | Left manipulator and nanoliter injection pump included, without adaptor, ear bars, holder and mask |
71000-S | Automated Stereotaxic Instrument, SGL.M | Left manipulator, without adaptor, ear bars, holder and mask | |
71001-D | Automated Stereotaxic Instrument, Dual.M, Automatic Injection | Two manipulators and nanoliter injection pump included, without adaptor, ear bars, holder and mask | |
71000-D | Automated Stereotaxic Instrument, Dual.M | Two manipulators, without adaptor, ear bars, holder and mask | |
Required accessories (optional)* | 68055 | Mouse Adaptor | |
68030 | Mouse/Neonatal Rat Adaptor | ||
68057 | Mouse Anesthesia Adaptor | ||
68021 | Rat Adaptor | ||
68053 | Rat Anesthesia Adaptor | ||
68301 | Rat 18° Ear Bars | ||
68306 | Mouse 60° Ear Bars | ||
68201 | Standard Probe Holder-Corner | ||
TRA-220 | Tissue Removal Optional Kit (220V ) | Optional when using tissue removal procedure, including needle connector, holder (68202), vacuum pump-GM-0.5Ⅱ -220V-50HZ, liquid storage tank, connecting tube, needle. | |
TRA-110 | Tissue Removal Optional Kit (110V ) | Optional when using tissue removal procedure, including needle connector, holder (68202), vacuum pump-GM-0.5Ⅱ -110V-50HZ, liquid storage tank, connecting tube, needle. | |
71000-LT | Laptop for Automated Stereotaxic Instrument (software included) | i3-1215U/8G/256G/WIN10/Set display/14″ |
*Indicates that other specifications can be selected, which can be viewed from the product catalog of RWD.